Kenco-engineering Magna-Site Magnetic Level Gauge (MLG-D) Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Capteurs Kenco-engineering Magna-Site Magnetic Level Gauge (MLG-D). Kenco Engineering Magna-Site Magnetic Level Gauge (MLG-D) User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 1
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
KENCO ENGINEERING COMPANY
P.O. BOX 470426, TULSA, OK 74147-0426
PHONE: (918) 663-4406 FAX: (918) 663-4480
http://www.kenco-eng.com e-mail: [email protected]
INSTALLATION PROCEDURES FOR THE SURFACE MOUNT
MAGNETIC LEVEL GAUGE (MLG-D)
1. Slip a 2” pipe flange gasket (not supplied) over float protection
housing tube and up against bottom surface of float protection
housing support ring.
2. Lower float protection housing per Item No. 6 down into tank until
flange gasket rests on top of existing 2” pipe flange.
3. Lower float assembly per Item No. 2 down into float protection
housing per Item No. 6 until bottom of magnet holder rests on top of
PVC float stop contained on PVC float rod. Note: Float should be
carefully forced down if tank contains liquid!
4. Pick up gauge housing per Item No. 1 and prepare to place on top of
float protection housing support ring. Notice that there are two 1/8”
dia. guide rods on inside of gauge housing.
5. Position magnet holder such that the north pole (red end) of magnet
is pointing toward the flag assembly side of gauge housing.
6. Align the slots in magnet holder with guide rods on inside of gauge
housing. This ensures that the magnet will always operate flags
correctly.
7. Install flange mounting studs (not supplied) to retain gauge
assembly in place.
Vue de la page 0
1

Résumé du contenu

Page 1 - KENCO ENGINEERING COMPANY

KENCO ENGINEERING COMPANYP.O. BOX 470426, TULSA, OK 74147-0426PHONE: (918) 663-4406 FAX: (918) 663-4480http://www.kenco-eng.com e-mail: info@

Commentaires sur ces manuels

Pas de commentaire